Chapter 8 ERROR MESSAGE

List of Messages

Data version unmatch error

Inconsistency of the version between machine and programmer causes this error. Set versions between
programmer and machine to identical ones. For how to exchange PROM of the programmer, refer to
"PROM Exchange Procedures"(page E-52).
A part of message is out of the indication box. The integral message is as described below:
"Data version unmatch error!! Press P key and after finished, please adapt the data version of PROM."

Received data error

When the received data is disrupted, this error occurs. Restart the programmer and receive the data
again.
Communication error
When communication fails, this error occurs. Restart the programmer and perform communication
again.

Data lost error

The error may occur if the power is not supplied in more than 1 month after the power is off. Press the
[ENTER] key when the error occurs. The data returns to defaults.