Toshiba PROSEC T1-16S User Manual page 147

Programmable controller basic hardware and function
Hide thumbs Also See for PROSEC T1-16S:
Table of Contents

Advertisement

FUN 029
Expression
Input
[ A
B
C+1 C ]
Function
When the input is ON, the data of A is multiplied by the data of B, and the result is stored in
double-length register C+1 C.
Execution condition
Input
OFF
No execution
ON
Execution
Operand
Name
X
A Multiplicand
B Multiplier
C Product
Example
When R005 is ON, the data of D0050 is multiplied by the data of RW05, and the result is
stored in double-length register D0101 D0100 (upper 16-bit in D0101 and lower 16-bit in
D0100).
If the data of D0050 is 1500 and the data of RW05 is 20, the result 30000 is stored in
D0101 D0100.
D0050
1500
RW05
20
Multiplication
Output
Operation
Device
Y
R
S
T.
C. XW YW RW SW T
Output
OFF
ON
Register
C
D
D0101 D0100
D0101
H0000
D0100
H7530
Basic Hardware and Function
6F3B0253
7. Instructions
Constant Index
I
J
K
30000
(upper 16-bit)
(lower 16-bit)
145