Available Dip Switch Settings (Parallel Interface) - Star Micronics SLIP SP298 SERIES Programmer's Manual

Slip printer
Hide thumbs Also See for SLIP SP298 SERIES:
Table of Contents

Advertisement

4

Available DIP switch settings (Parallel Interface)

The following table shows all the possible settings for the DIP switch. The
factory default settings are ON for switches 1 through 7 and OFF for switch 8.
Switch
1
Pin 31 / Pin 36 Reset Signal
2
3
4
5
6
7
Command Emulation
8
Reset Signal
Pin 31 is enabled.
Pin 31/Pin 36 are enabled.
Disabled
Disabled
A reset can be performed with pin 31 on the interface by setting DIP switch 1 to
ON (the factory default setting).
In addition, when a reset can be performed with pin 31, setting DIP switch 2 to
OFF sets up the unit to perform a reset when pin 31 and pin 36 are "LOW".
Command Emulation
Star mode
ESC/POS (TM-295)
ESC/POS (TM-290)
Not used (*1)
*1: Never set switch 7 to OFF at the same time that switch 8 is set to ON.
Parameter
Not used
Switch 1
Switch 7
ON
See table below.
(Always ON)
See table below.
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
Switch 2
ON
OFF
ON
OFF
Switch 8
ON
OFF
OFF