Error Code Message Information
ASR0106
Message The watchdog timer expired.
Details
The operating system or an application failed to communicate within the time-out period.
Action
Check the operating system, application, hardware, and system event log for exception
events.
ASR0107
Message The watchdog timer pre-timeout interrupt was initiated.
Details
The operating system or an application failed to communicate within the time-out period.
Action
Check the operating system, application, hardware, and system event log for exception
events.
BAT0000
Message
The system board battery is low.
Details
The system board battery is either missing, bad, or unable to charge due to thermal issues.
Action
Check system fans. Replace the system board battery.
BAT0002
Message
LCD Message
Details
Action
BAT0004
Message
LCD Message
Action
BAT0005
Message
Details
Action
BAT0007
Message
LCD Message
Details
Action
BAT0010
Message
Details
Action
86
The system board battery has failed.
The system board battery has failed. Check battery.
The system board battery is either missing or bad.
See
Getting
Help.
The system board battery is absent.
The system board battery is absent. Check battery.
Reinstall the system board battery.
The storage battery is low.
System has to remain powered on to charge the battery.
Allow the battery to charge. If the issue persists, see
The storage battery has failed.
The storage battery has failed. Check battery.
Verify the cable connection between the storage battery and the controller.
Verify the storage battery installation.
The storage battery for disk drive bay <
System has to remain powered on to charge the storage battery.
Allow the storage battery to charge. If the issue persists, see
Getting
Help.
bay > is low.
Getting
Help.

Advertisement