Error Code Message Information
TMP0119
Message
LCD Message
Details
Action
TMP0120
Message
LCD Message
Details
Action
TMP0121
Message
LCD Message
Details
Action
TMP0122
Message
LCD Message
Details
Action
TMP0100
Message
Details
Action
TMP0104
Message
LCD Message
Details
Action
TMP0126
Message
LCD Message
Details
Action
TMP0128
Message
126
The system inlet temperature is less than the lower critical threshold.
System inlet temperature is outside of range.
Ambient air temperature is too cool.
Check the system operating environment.
The system inlet temperature is greater than the upper warning threshold.
System inlet temperature is outside of range.
Ambient air temperature is too warm or one or more fans may have failed.
Check the system operating environment and review event log for fan failures.
The system inlet temperature is greater than the upper critical threshold.
name > temperature is outside of range. Check Fans.
System inlet <
Ambient air temperature is too warm or one or more fans may have failed.
Check the system operating environment and review event log for fan failures.
The system inlet temperature is outside of range.
name > temperature is outside of range. Check Fans.
System inlet <
Ambient air temperature is too warm or cool.
Check the system operating environment and review event log for fan failures.
Disk drive bay temperature is less than the lower warning threshold.
Ambient air temperature is too cool.
Check the system operating environment.
Disk drive bay temperature is less than the lower critical threshold.
Disk drive bay temperature is outside of range. Check Fans.
Ambient air temperature is too cool.
Check the system operating environment.
Disk drive bay temperature is greater than the upper warning threshold.
Disk drive bay temperature is outside of range. Check Fans.
Ambient air temperature is too warm or one or more fans may have failed.
Check the system operating environment and review event log for fan failures.
Disk drive bay temperature is outside of the allowable range.