Dell PowerEdge M820 Owner's Manual page 84

Dell poweredge m820 systems owner's manual
Hide thumbs Also See for PowerEdge M820:
Table of Contents

Advertisement

Error Code Message Information
AMP0322
Message
Details
Action
ASR0000
Message The watchdog timer expired.
Details
The operating system or an application failed to communicate within the time-out period.
Action
Check the operating system, application, hardware, and system event log for exception
events.
ASR0001
Message The watchdog timer reset the system.
Details
The operating system or an application failed to communicate within the time-out
period. The system was reset.
Action
Check the operating system, application, hardware, and system event log for exception
events.
ASR0002
Message The watchdog timer powered off the system.
Details
The operating system or an application failed to communicate within the time-out
period. The system was shut down.
Action
Check the operating system, application, hardware, and system event log for exception
events.
ASR0003
Message The watchdog timer power cycled the system.
Details
The operating system or an application failed to communicate within the time-out
period. The system was power-cycled.
Action
Check the operating system, application, hardware, and system event log for exception
events.
ASR0008
Message The watchdog timer interrupt was initiated.
Details
The operating system or an application failed to communicate within the time-out period. No
action was taken.
84
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see
Chassis power level current is outside of range.
Chassis power level current is outside of the optimum range.
1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see
Getting
Help.
Getting
Help.

Advertisement

Table of Contents
loading

Table of Contents