Thread Breakage Sensor - Brother BES-1260BC Instruction Manual

9 needles/12 needles
Hide thumbs Also See for BES-1260BC:
Table of Contents

Advertisement

Thread Breakage Sensor

The sensor for thread breakage can be turned ON/OFF or the sensor sensitivity for
each needle bar can be set.
The sensitivity can be set within the range of 1 - 100. The smaller the value is,
the higher the sensitivity is.
1.
Select [Thread Breakage Sensor] from Setting menu.
2.
Click the head you want to disable the sensor and remove the check mark ( ).
3.
Adjust the sensor sensitivity.
4.
Click [OK].
BES-960BC BES-1260BC
Chapter 6 Embroidering
The sensor sensitivity
for each needle bar is
adjusted individually.
All sensor sensitivities
for all needle bars are
adjusted simultaneously.
151