Trunk Card Specifications - NEC NEAX 2000 IPS Reference Manual

Request for proposal (rfp)
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

Chapter 6 Trunking
Trunk Parameters
Trunk Impedance 600/900 ohms (selectable by programming)
Trunk Resistance Characteristics, Central Office Trunk (1200
o Trunk Set Up Procedure
o Loop Start
o Ground start
o Wink Start
o Ring Down
o E & M Signaling
Release and Incoming Detect Immediate Start and Timing Variable Start

Trunk Card Specifications

PN-4COTB
This card provides 4 Loop/Ground Start trunks with disconnect supervision and mounts in any PIM (0 to
7) and supports the following interface:
a. Interface for standard Analog trunks/Centrex type lines
b. Interface card for CO ring down trunks
c. Interface with 4 paging equipment lines
d. Interface with external music/announcement source for Music-On-Hold feature
The above interfaces can be mixed on to one card in any combination.
PN-8COTS
This card provides 8 Loop/Ground Start trunks with disconnect supervision and mounts in any PIM (0 to
7) and supports the following interface:
a. Interface with 8 CO lines
b. Interface with 8 paging equipment lines
c. Interface with external music/announcement source for Music-On-Hold feature.
The above interfaces can be mixed on to one card in any combination.
PN-4COTG
This card is used to provide the system with Caller ID (Class SM). This feature requires the SPN-
4RSTC card to receive the FSK signals for Caller ID. This 4-port card mounts in any PIM (0 to 7). This
card supports Loop Start trunks.
PN-8COTQ
This card is used to provide the system with Caller ID (Class SM). This feature requires the SPN-
4RSTC card to receive the FSK signals for Caller ID. This 8-port card mounts in any PIM (0 to 7). This
card supports Loop Start trunks
Page 6-2
.
maximum)
NEAX 2000 IPS Request for Proposal (RFP) Reference Guide
NDA-24349, Issue 4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents