Safety Considerations - Carrier 50PD05 Operating And Service Instructions

Single package displacement ventilation or single zone variable airflow rooftop units electric cooling/gas heating with puron (r-410a) refrigerant and comfortlink 1.x controls
Hide thumbs Also See for 50PD05:
Table of Contents

Advertisement

Variable Frequency Drive (VFD) ......................
53
Integrated Gas Control (IGC) Board
...................
54
Low Voltage Terminal Strip (TBI) .....................
55
Scrolling Marquee Display
..........................
56
Accessory Navigator
TM
Display .......................
56
Carrier Comfort Network (CCN)® Interface .............
56
Field-Installed Accessories
..........................
56
SERVICE .........................................
59
Cleaning
........................................
60
Lubrication
......................................
62
Evaporator Fan Service and Replacement
...............
62
Evaporator Fan Performance Adjustment
...............
62
Evaporator Fan Belt Tension Adjustment
...............
63
Variable Frequency Drive (VFD) Replacement
...........
63
Condenser-Fan
Adjustment ..........................
63
Verify Sensor Performance
..........................
64
Economizer Operation During Power Failure
............
64
Evacuation .......................................
64
Refrigerant Charge .................................
64
Gas Valve Adjustment (48PD Units Only) ...............
65
High Altitude (48PD Units Only) .....................
66
Main Burners (48PD Units Only) .....................
66
Filter Drier .......................................
66
Protective Devices .................................
66
Relief Devices ....................................
67
Compressor Sound Shield ...........................
67
Control Circuit, 24-V
..............................
67
Replacement Parts .................................
67
Diagnostic LEDs ..................................
67
APPENDIX A - LOCAL DISPLAY AND
CCN TABLES
.....................................
68
APPENDIX B - STARTUP DATA .....................
81
APPENDIX C - ADDITIONAL STARTUP DATA .........
91
APPENDIX D - ADDITIONAL
STARTUP DATA .......
100
UNIT START-UP CHECKLIST
......................
105
SAFETY
CONSIDERATIONS
Installation and servicing of air-conditioning
equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified service personnel should install, repair, or
service
air-conditioning
equipment.
Untrained
personnel
can
perform the basic maintenance
functions
of replacing
filters.
Trained service personnel should perform all other operations.
When working on air-conditioning equipment, observe precautions
in the literature, tags and labels attached to the unit, and other
safety precautions that may apply. Follow all safety codes. Wear
safety glasses and work gloves. Use quenching cloth for unbrazing
operations.
Have
fire extinguishers
available
for all brazing
operations.
Follow all safety codes. Wear safety glasses and work gloves.
Have
fire
extinguisher
available.
Read
these
instructions
thoroughly and follow all warnings or cautions attached to the unit.
Consult local building codes and National Electrical Code (NEC)
for special requirements.
Recognize
safety information.
This is the safety-alert
symbol
/_.
When
you
see this symbol
on the
unit
and in instructions
or
manuals,
be alert to the potential
for personal
iniury.
Understand
the
signal
words
DANGER,
WARNING,
and
CAUTION.
These words
are used with
the safety-alert
symbol.
DANGER
identifies
the most serious
hazards
which
will result in
severe
personal
iniury
or death.
WARNING
signifies
a hazard
which
could
result in personal
iniury or death. CAUTION
is used
to identify
unsafe
practices
which
may
result
in minor
personal
iniury or product
and property
damage.
NOTE
is used to highlight
suggestions
which will result in enhanced
installation,
reliability,
or
operation.
ELECTRICALSHOCK
HAZARD
Failure to follow this warning could cause personal
iniury or death.
Before performing
service or maintenance
operations
on unit, turn off main power switch to unit and install
lockout tag. Ensure electrical service to rooftop unit
agrees with voltage and amperage listed on the unit
rating plate.
UNIT DAMAGE HAZARD
Failure
to follow
this
caution
may cause equipment
damage.
This unit uses a microprocessor-based
electronic control
system. Do not use jumpers or other tools to short out
components
or to bypass
or otherwise
depart
from
recommended
procedures.
Any short-to-ground
of the
control board or accompanying
wiring may destroy the
electronic modules or electrical components.
FIRE,
EXPLOSION
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury, death and/or property
damage.
Improper
installation,
adjustment,
alteration,
service,
or
maintenance
can
cause
property
damage,
personal
iniury,
or loss of life. Refer
to the User's
Information
Manual
provided
with this unit for more details.
Do not store or use gasoline
or other flammable
vapors
and liquids
in the vicinity
of this or any other appliance.
What
to do if you smell gas:
1. DO NOT try to light any appliance.
2. DO NOT touch any electrical
switch, or use any
phone in your building.
3.IMMEDIATELY
call your gas supplier
from a
neighbor's
phone. Follow
the gas supplier's
instructions.
4. If you cannot reach your gas supplier,
call the fire
department.