Denso BHT-7500S User Manual page 157

Bar code handy terminal
Table of Contents

Advertisement

Data Text Format
(1) Heading text
Byte
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
position
Example of
M A S T E R
contents
The data file name should be a
maximum of 12 characters in length
and it consists of FILE NAME and
.EXTENSION. The FILE NAME should
be 1 to 8 characters. The EXTENSION
should be other than .PD3, .FN3, and
.EX3, and it may be omitted (together
with a period).
To transfer a data file containing a data field(s) of 100 digits or more, use the
Win32 API-based Transfer Utility. The MS-DOS–based Transfer Utility does not
support transmission of data fields exceeding 99 digits.
(2) Data text
Data field 1
Example of
T 1 0 0 9 1 S 1 2 3
contents
Every data field should be
1 to 254 digits in length.
The total length of all data fields plus the number of the character count bytes (= the
number of the fields) should be 255 bytes or less.
When you transfer five 50-digit (50-byte) fields, for example, the total length of all
data fields is 250 (50 x 5) bytes and the number of the character count bytes is 5.
Accordingly, the total is 255, so you can transfer the file.
Data file name
(12 bytes)
.
D A T
If the data file name is less
than 12 characters in length,
the lower blank bytes will be
filled with space characters.
Data field 2
If a data field is less than
the maximum digits in
length, the lower blank
bytes will be filled with
space characters.
Chapter 3. Communications Operations of the BHT
Number of fields
(2 bytes)
Number of data
texts contained
(5 bytes)
0 0 5 9 2
The number of data
texts should be 0 to
32767. If it is less than 5
digits, the upper blank
bytes will be filled with
zeros (0).
The number of fields should be 1
to 16. If it is less than 2 digits, the
upper blank byte will be filled with
zero (0).
9 2 0 2 1 4 1 3 2 5
137
Length of
data field 1
Length of
data field n
(2 bytes)
(2 bytes)
n
0 6
1 0
Every data field should be
1 to 254 digits in length. If
it is less than 2 digits, the
upper blank byte will be
filled with zero (0).
If a data field is 100 to 199
digits in length, @0 to I9
will be given; if it is 200 to
254 digits, P0 to U4 will be
given.
@
20X
P
10X
A
21X
Q
11X
B
12X
24X
T
H
25X
U
18X
19X
I
Data field n

Advertisement