Truncate Leading/Ending - Datalogic QuickScan QS6500 Product Reference Manual

Hide thumbs Also See for QuickScan QS6500:
Table of Contents

Advertisement

Telepen — continued

Truncate Leading/Ending

The leading or ending digits of bar code data characters can be trun-
cated. Select from 00 (no truncation) to 15.
The imager will beep instead of reading anything when
the truncate value is more than the bar code data digits
or the truncate leading value overlaps the truncate end-
ing value.
NOTE
START
MODE
Sets from 00 to 15 characters to truncate from either the leading or ending charac-
ters of scanned bar code data. To configure this feature, scan the "START" bar
code above to place the unit in Programming Mode, then the SET TRUNCATION:
LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alpha-
numeric table in
Appendix B, Alpha-Numeric Pad
quantity of digits to trumcate from the message string. Accept your selection by
scanning the "SET" bar code below and finally, exit programming mode by scan-
ning the "END" barcode below.
DEFAULT SETTING FOR THIS FEATURE: 00 (None)
Set Truncation:
Leading
Set Truncation:
Ending
SET
END
Product Reference Guide
BARCODE
representing the desired
Telepen
6-159

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quickscan qs6500btQuickscanqs6500bt

Table of Contents