Code I.D. Selection

The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted Codabar bar code data depending on how this feature is enabled.

Example: Setting the Codabar Code I.D.

To configure this feature:
1. Determine which character(s) you would like to use to represent
the Codabar symbology. Reference
to find the corresponding hex values for your chosen charac-
Chart
ter(s). In this example we'll set a Code I.D. of "%" (the percent
sign) to represent Codabar. The value from the table correspond-
ing to '%' is 25. This value will be used in a step to follow.
2. Scan the START bar code
3. Scan the SET CODABAR CODE I.D. bar code.
4. Turn to
Appendix B, Alpha-Numeric Pad
and '5' (the value determined in an earlier step to represent '%').
5. Scan the SET bar code to accept the digits scanned.
6. Turn to the
Data Editing
TION: BEFORE BAR CODE DATA label.
Features configured using the
universal and will affect all symbologies.
NOTE
7. Scan the END bar code to exit Programming Mode.
8. The resulting message string for scanned Codabar labels would
appear as follows:
Scanned bar code data:
Resulting message string output: %0123456789123
Product Reference Guide
Appendix A, ASCII Conversion
and scan the bar codes '2'
chapter and scan the CODE ID POSI-
Data Editing
0123456789123
Codabar
chapter are
6-119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quickscan qs6500btQuickscanqs6500bt

Table of Contents