Code I.d. Selection; Example: Setting The Rss-14 Code I.d - Datalogic QuickScan QS6500 Product Reference Manual

Hide thumbs Also See for QuickScan QS6500:
Table of Contents

Advertisement

RSS-14 — continued

Code I.D. Selection

The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted RSS-14 bar code data depending on how this feature is enabled.

Example: Setting the RSS-14 Code I.D.

To configure this feature:
1. Determine which character(s) you would like to use to represent
the RSS-14 symbology. Reference
to find the corresponding hex values for your chosen charac-
Chart
ter(s). In this example we'll set a Code I.D. of "R4" to represent
RSS-14. The value from the table corresponding to ''R' is 52 and
the value for '4' is 34. These values will be used in a step to follow.
2. Scan the START bar code
3. Scan the SET RSS-14 CODE I.D. bar code.
4. Turn to
Appendix B, Alpha-Numeric Pad
and '2' (the value determined in an earlier step to represent 'R').
Then scan the bar codes '3' and '4' (hex equivalent for '4').
5. Scan the SET bar code to accept the digits scanned.
6. Turn to the
Data Editing
TION: BEFORE BAR CODE DATA label.
Features configured using the
universal and will affect all symbologies.
NOTE
7. Scan the END bar code to exit Programming Mode.
8. The resulting message string for scanned RSS-14 labels would
appear as follows:
Scanned bar code data:
Resulting message string output: R40123456789123
Product Reference Guide
Appendix A, ASCII Conversion
and scan the bar codes '5'
chapter and scan the CODE ID POSI-
Data Editing
0123456789123
RSS-14
chapter are
6-45

Hide quick links: