1-18 RAID Array 3000 Pedestal Storage Subsystem Hardware User's Guide
Pedestal Physical and Power Specification
Item
Height
Width
Depth
Rear clearance (air exhaust)
Front clearance (door opening)
Weight (no devices)
Item
Input power
Heat dissipation
Temperature (optimal, minimum required)
Altitude
Air quality
Total power per power supply
(Total of +12 VDC and +5 VDC outputs)
Nominal output voltages
Device startup time
Table 1-7
Physical Specifications
Power Specifications
110-240 VAC, 50/60 Hz, single
phase, 12A/6A
3070 Btu/hr
65°F to 75°F (18 C to 24 C),
50°F to 104°F (10 to 40 C)
Up to 2,400 m
Not to exceed 500,000 particles/ft3
for air at a size of 0.5 micron or
larger
204 watts, maximum
+5 VDC @ 15 amps, maximum
+12 VDC @ 12 amps, maximum
4 second internal, minimum
Dimension
564 mm
254 mm
494 mm
305 mm
305 mm
19.5 kg
Rating