FAULT / ERROR CODES DESCRIPTION

Fault / Error Code
E001
E005 / E039
E006
E007
E008 / E011
E009
E010
E012
E013
E014
E015
E016
E019
E020
E021
E024
E030
E034
E035
E036
E038
E039
E040
E041
E042
E043 / E044 / E045
Electronic thermal overload error (motor current > bC110)
This error occurs if an operation command has been input to the inverter when the power supply is
turned ON. Operation command detection is carried out for 1 second after the power supply is turned
Incoming voltage error (input power supply is too high)
Temperature error Cooling fan rotation speed reduction error
When [bb-65] input phase loss selection is set to 01, and when a missing phase is detected in input line,
IGBT error (ground fault to motor or on output of VFD)
When the output phase loss selection [bb-66] is set to 01, when a loose connection or disconnection of
output line, disconnection inside the motor, etc. is detected, the inverter turns OFF its output.
Detection of phase loss state is executed in the section between 5Hz to 100Hz.
Electronic thermal overload error (motor current > bC110)
RS485 / EZCOM communication error When CF-05 = 0 or 1
Description
Over-current error
Dynamic braking resistor over used error
DC-Bus over-voltage error
Memory error / CPU error
Undervoltage error
Built-in current detector error
External trip error (digital input configured for Ext)
USP error
ON. (When USP function is selected.)
Ground fault error
Instantaneous power failure error
Temperature detector error
Temperature error
Input open-phase error
the inverter turns OFF its output.
Output open-phase error
Thermistor error
Brake error
Low-speed range overload error
Operator keypad communication error
RTC error
Internal Program illegal instruction error
Page 50