Gerber ODYSSEY XP Owner's Manual page 65

Plotter
Table of Contents

Advertisement

Error codes
The control panel displays
number. The error code numbers and their meanings are listed in the
table below.
Error / Failure
1
ROM
2
RAM
3
Unknown plotter
ID
4
Power relay stuck
shut
5
Power relay stuck
open
6
Display failure
7
FPGA failure
8
FPGA Data
Checksum error
9
FPGA Wrong
Version error
10
Heartbeat internal
failure
11
Encoder reset failed
12
X axis power,
encoder or wiring
failure
13
X2 axis power,
encoder or wiring
failure
14
Y axis power,
encoder or wiring
failure
System Error
Meaning
Read-Only Memory is
damaged.
Random-Access
Memory is damaged.
Jumpers indicate an
incorrect type of plotter.
Power relay
malfunction.
Power relay
malfunction.
Display not responding.
Custom chip
malfunction.
Bad FPGA data file or
bad FPGA chip
Bad FPGA data file or
bad FPGA chip
Electrical control board
failure.
Encoder chip failure.
Check X axis (fixed
motor) encoder and
power connectors.
Check X2 axis (moving
motor) encoder and
power connectors.
Check Y axis encoder
and power connectors.
followed by an error code
Correction
Contact Field Service.
Contact Field Service.
Call Field Service if retry fails.
Turn power off and on. Call
Field Service if retry fails.
Turn power off and on. Call
Field Service if retry fails.
Retry. Call Field Service if
retry fails.
Retry. Call Field Service if
retry fails.
Reflash FPGA data.
Check versions of O/S and
FPGA files.
Replace control board.
Reflash FPGA data.
Check versions of O/S and
FPGA files.
Replace control board.
Retry. Call Field Service if
retry fails.
Retry. Call Field Service if
retry fails.
Contact Field Service.
Contact Field Service.
Contact Field Service.