Gerber ODYSSEY XP Owner's Manual page 64

Plotter
Table of Contents

Advertisement

58
CHAPTER 6
Troubleshooting
Error example 1
The first example of an error message is shown below. Pressing F2
restarts the internal plotter system. If the message reappears, consult the
Error Codes table, which begins on the next page. Look up the system
error number and perform the correction listed.
Error example 2
The second example of an error message is shown below.
1 Press F4, Resume. The plotter tries to correct the error condition
without restarting.
2 If the same message re-appears, press F2 to restart the software.
3 If the message again re-appears, consult the Error Codes table, which
begins on the next page. Look up the system error number and follow
the correction listed.
Error example 3 (Display is blank)
If the display is blank, you can determine the error condition by
following the steps below.
1 If the plotter is beeping, press ENTER to stop the sound.
2 Press the F1 key and count the number of beeps. The count indicates
the TENS digit of the error number. No beeps means the error number
is less than 10.
3 Press the F2 key and count the number of beeps. The count indicates
the ONES digit of the error number.
4 Combine the digits to determine the error number. For example, if F1
makes 2 beeps and F2 makes 5 beeps, the system error is 25.
5 Consult the Error codes table, which begins on the next page. Look up
the system error number and follow the correction listed.
SYSTEM ERROR: 10
X Pwr / Encoder Wiring
RESTART
Press F2
SYSTEM ERROR: 37
Z Axis Home Error
RESTART
RESUME
Press F2 or F4

Hide quick links: