Reloading factory defaults for all materials
Materials are reset to default settings for that material. Custom materials
are reset to Scotchcal 220 settings.
To reload factory defaults
1 Press F3 while holding down the ENTER key for the Operational
Setup menu.
2 Press F4, Misc., to get the Misc Settings menu.
3 On the Misc Settings menu, press F4, Default.
4 Press F3, YES, to reset the settings for all materials to the factory
defaults, or F4, NO, to return to the Misc Settings menu without
making any changes.
Reloading factory defaults for all settings
To return all settings to the factory defaults, hold down the F1 and
CANCEL keys while powering up the plotter. The factory defaults are
shown in the tables.
Note: The values listed in the tables are for Scotchcal 220, which is the default
material type. Other materials will have their appropriate values.
Tool settings
Speed
18 in/sec
46 cm/sec
OPERATIONAL SETUP
Settings
ENTER for Main Menu
MISC SETTINGS
Repeats
Pulldown
ENTER for Main Menu
Acceleration
3.0 g
System
F4
Misc.
Pounce
Default
F4
Force
Corners
3.5 ounces
0.020"
99 grams
0.05 cm