Cloth Clamp Height - Duerkopp Adler 558 Service Instructions Manual

Table of Contents

Advertisement

11. Cloth Clamp Height

1
2
3
4
5
The clearance between the upper cloth clamps 2 and the lower cloth
clamps 3 should be 10 mm.
The clearance is set with the gauge 3 (Order no. 558 1633) eingestellt.
Caution Risk of Injury !
Pull the mains plug before setting.
Loosen lock nut 4.
Place the gauge under the upper cloth clamps 2.
Set the clearance by turning the stop screw 5.
Tighten lock nut 4 again.
ATTENTION !
The faultless functioning of the clamp closing lever 1 is dependent on
the precise settings of chapters 11 to 15.
If one of these settings is changed, then all settings for chapters 11 to
15 (in this order) must be made.
15