21.3 Setting the Securing Blocks

28
1
2
3
4
The securing blocks 2 prevent a sliding of the clamping plates out of
their spread positions during the cutting and sewing procedures.
Caution Risk of Injury !
Pull the mains plug before setting.
With closed and spread clamping plates loosen screws 1.
Bring the securing blocks 2 into contact with bracket 4 and the
spring-mounted catch bolt 3. The securing blocks should, however,
exert no pressure on the bracket thereby.
Screws 1 again.
Repeat the spreading procedure with closed clamps.
The spring-mounted catch bolt 3 must thereby jump in front of the
securing blocks 2.
Check if the securing blocks 2 can move unhindered over catch
bolt 3 with open clamping plates.