3. Turn-off Lever
6
1
2
3
4
5
6
7
8
9
10
11
12
The turn-off lever 1 is set with the gauge (Order no. 558 1635).
Caution Risk of Injury !
Pull the mains plug before setting.
–
Loosen screw 11.
–
Set stop 9 as far forward as possible.
–
Loosen screw 2.
–
Press the turn-on link 3 manually to the back.
The idle lever 8 fall downward and encompasses with its groove
the pin 5.
–
Hold the idle lever 8 down.
At the same time turn the hand crank drehen until the roller 6 of the
turn-on link 3 reaches the highest point of the overrun surface 7 of
the length setting slide.
–
Tighten screw 2 again.
–
Loosen screws 4.
–
Between the setting plate 10 of the turn-off lever 1 and square
stone 12 set a clearance of 0.5 mm.
Use the gauge for this.
When the edge is worn (after a longer period of switching use) turn
the square stone 90°.
The correct position of the square stone is always shown by a
groove.
–
Tighten screws 4 again.