GS ( K pL pH fn m
[Function]
Selecting print control method
[Outline]
Executes the setting related to the print control specified by the value of "fn".

fn = 48: Function 48 Setting Print Control Mode

GS ( K pL pH fn m
[Code]
<1D>H<28>H<4B>H<pL><pH><fn><m>
[Range]
(pL+pH×256)=2 (pL=2、pH=0)
fn=48
0≦m≦4、48≦m≦52
[Outline]
Sets print control mode.
[Default]
m=1
Function No. (fn)
Function 48
Function 49
Function 50
Function 97
m
0,48
Selects the print control mode at power on.
1,49
Sets print control mode 1 (standard)
2,50
Selects the print control mode at power on.
3,51
Selects the print control mode at power on.
4,52
Selects the print control mode at power on.
Function
Sets print control mode.
Sets printing density.
Sets printing speed.
Sets the number of divisions for head conducting.
Print Control Mode