Fn = 6: Function 6 Sending The Set Customized Value - Citizen PPU-700 Command Reference Manual

Printer presenter unit
Hide thumbs Also See for PPU-700:
Table of Contents

Advertisement

fn = 6: Function 6 Sending the Set Customized Value

GS ( E pL pH fn a
[Code]
<1D>H<28>H<45>H<pL><pH><fn>[a]
[Range]
(pL+pH×256)=2 (pL=2、pH=0)
fn=6
a=1、2、5、6、97、116、117
[Outline]
• Sends the set value of customized value set by "a".
• Configuration of customized value No.
• a = 1: When user NV memory capacity is specified*
Header
ID
Customized value No.
Separation number
Customized value
NULL
Sending Data
a
1st Byte
1
49("1")
2
50("2")
5
53("5")
6
54("6")
97
57("9")
116
49("1")
117
49("1")
Setting Status
Stored
Memory
Value
Capacity
1
1K bytes
2
64K bytes
3
128K bytes
4
192K bytes
Hex.
37H
27H
30H~39H
1FH
30H~39H
00H
2nd Byte
3rd Byte
55("7")
49("1")
54("6")
49("1")
55("7")
1st Byte
2nd Byte
49("1")
50("2")
51("3")
52("4")
- 100 -
No. of Data
1
1
1~3
1
1~5
1
Sending Data
3rd Byte
4th Byte
5th Byte

Advertisement

Table of Contents
loading

Table of Contents