12) Remove the 2 screws, then take out the
duplex feed motor from the inside.
Screws
Duplex feed motor
Figure 3-10-21
9. Removal of the reversing motor
1) Follow the steps 1) through 10) in the
duplex feed motor removal procedures
to remove the lower reversing guide.
2) Disconnect the connector and then dis-
engage the cable from the cable guide.
Connector
Cable
Cable guide
Figure 3-10-22
3) Remove the 2 screws, then take out the
reversing motor from the inside.
Screws
Reversing motor
Figure 3-10-23