CHAPTER 3
B. Paper Size Detection PCB
1) Remove the pick-up module according
to the steps 1) through 12) on page 3-5.
2) Disconnect the 2 connectors.
3) Remove the 9 screws and then the
cover.
Connectors
Screws
Cover
Figure 3-7-4
4) Unhook the 2 claws, and then remove
the cover.
Claws
Cover
Figure 3-7-5
3 - 28
5) Disconnect the connector.
6) Unhook the 2 claws and take out the
paper size detection PCB.
Connector
Claws
Paper size detection PCB
Figure 3-7-6