B.

Operation of Fixing Assembly Temperature Control System

Power switch ON
WARM-UP
Main motor (M1)
Scanner cooling fan (FM1)
Exhaust fan (FM2)
Fixing roller heater (H1)
COPY START key indicator
Blinks green
195˚C
180˚C
155˚C
110˚C
50˚C
0˚C
Note:
When the preheat mode starts in response to a press on the STANDBY key, the fixing tem-
perature is controlled to 155°C.
COPYRIGHT © 1999 CANON INC.
50˚C
110˚C
WARM-UP
STAND-BY
ROTATION
Glows green
Figure 6-102
CANON NP6317 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 FIXING SYSTEM
COPY START key ON
SCANNER
SCANNER
SCANNER
FORWARD
REVERSE
FORWARD
Glows red
SCANNER
LAST
STAND-BY
REVERSE
ROTATION
Glows green