ETHCNTR Messages

This section contains the Ethernet controller messages. These messages result from a failure of the
switch software when trying to program the hardware and lead to incorrect switch behavior.
Error Message ETHCNTR-3-HALF_DUX_COLLISION_EXCEED_THRESHOLD: Collision at [chars]
exceed threshold. Consider as loop-back.
Error Message ETHCNTR-3-LOOP_BACK_DETECTED:, Loop-back detected on [chars]. The port
is forced to linkdown.
Error Message ETHCNTR-3-NO_HARDWARE_RESOURCES: Not enough hardware resources.
Shutting down [chars].
OL-13020-01
The collisions at a half-duplex port exceeded the threshold, and the port is treated as a
Explanation
loopback. On switches that support Power over Ethernet (PoE), this message might be displayed
when a device that can be powered by either a PoE switch port or by AC power is not being powered
by an external AC power source and is connected to a port that has been configured with the power
inline never interface configuration command. [chars] is the port where the threshold was exceeded.
On switches that support PoE, remove the device or configure the port by
Recommended Action
entering the power inline auto, shutdown, and no shutdown interface configuration commands.
No action is required on non-PoE switches. The port goes into error-disabled mode until the problem
is resolved.
Explanation
This message occurs when a keepalive packet is looped back to the port that sent the
keepalive. The loopback condition might be caused by a balun cable being accidentally connected
to the port, or there might be a loop in the network. [chars] is the port.
Recommended Action
Examine the cables. If a balun cable is connected, and the loopback condition
is desired, no action is required. Otherwise, connect the correct cable, and bring the port up by
entering the no shutdown interface configuration command. We do not recommend using the no
keepalive interface command to disable keepalives. The cause of this network loop must be found
and corrected. Although disabling keepalives prevents the port from being error disabled, it does not
resolve the cause of the problem and can affect network stability. See
information.
Explanation
There are too many VLANs and routed ports (if the switch supports routed ports)
configured. [chars] is the short interface name, or the VLAN name, such as VLAN0002.
Recommended Action
Reduce the total number of VLANs and routed ports to less than 1023. To
preserve configuration and connections across reboots, save the configuration.
CSCea46385
Cisco IE 3000 Switch System Message Guide