Central Site of a Multi-site Configuration
Diagram of Related Functions: Call Collection Interface, Call Sender Interface, Users
MERLIN
LEGEND
System A
Central Site
MERLIN
LEGEND
Reporter
Central Site
Call Collection Interface - Central Site
protocol = Direct Connect
format = MERLIN LEGEND
Reporter
Protocol Options (Direct Connect)
Port = Com3
Baud rate, data bits, etc.
Call Collection Interface - Site 1
protocol = PollComm
format = MERLIN LEGEND
Reporter
Protocol Options (PollComm)
Port = Com4
Remote phone # = 999-1234
Remote User ID = Central
Remote Password = Poller
Call Collection Interface - Site 2
protocol = PollComm
format = MERLIN LEGEND
Reporter
Protocol Options (PollComm)
Port = Com4
Remote phone # = 999-5678
Remote User ID = UserId
Remote Password = UserPswd
com3
com4
Modem
Modem
com1
(999-1234)
com2
DTE in
Modem
DCE out
(999-1234)
Remote Site #1
Call Collection Interface
protocol = Direct Connect
format = MERLIN LEGEND
Reporter
[x] save call data for sending
Protocol Options (Direct
connect)
Port = Com2
Baud rate, data bi
Call Sender Interface
Port = Com1
Baud rate = modem's
Users
User ID = Central
Remote Site #2
PSU (default) login by poller:
User ID = UserId
Password = UserPswd
Issue 1 January 1997
Site 1
MERLIN
LEGEND
Reporter PC
MERLIN
LEGEND
System B
MERLIN
LEGEND
System C
Site 2
PSU
ts, etc.
8-7