Sign In
Upload
Manuals
Brands
Lucent Technologies Manuals
Multiplexer
Metropolis
Lucent Technologies Metropolis Manuals
Manuals and User Guides for Lucent Technologies Metropolis. We have
2
Lucent Technologies Metropolis manuals available for free PDF download: Installation Manual, Brochure
Lucent Technologies Metropolis Installation Manual (532 pages)
DMX Access Multiplexer
Brand:
Lucent Technologies
| Category:
Multiplexer
| Size: 6 MB
Table of Contents
Table of Contents
7
About this Document
23
Overview
23
About this Document
24
Safety Information and Instructions
27
Figure 1 Static Control Wrist Strap
29
Important Safety Instructions
31
Related Documentation and Training
34
Table 1 Metropolis DMX Documentation Set
34
Table 2 Metropolis DMX Drawings
35
How to Comment on this Document
37
How to Order Documents
38
Technical Support Services Xl
40
Part I Metropolis DMX Access Multiplexer Physical Installation and Powering
41
Overview
41
Metropolis ® DMX Shelf Backplane
42
Figure 0-1 DMX Shelf Backplane
42
Figure 2-2 Metropolis ® DMX Shelf
42
Figure 7-1 Metropolis DMX Shelf Backplane
42
Tools, Test Equipment and Accessories
43
Part I Metropolis ® DMX Access Multiplexer
42
Overview
47
Planning
49
Table 1-1 Cable Requirements and Options
50
Connector References
52
Figure 1-1 Connector Types and Pinouts
52
Inspection
53
Metropolis ® DMX Shelf Installation
54
Figure 1-4 Metropolis ® DMX Shelf Mounted to the Rear of a 23-Inch Frame
57
DMX Bay Mounting Arrangements
59
Fan Shelf Installation and Cabling
61
Figure 1-6 Fan Unit Removal
62
Figure 1-7 Fan Shelf Mounting Brackets Positions
63
Figure 1-8 Fan Shelf Positioning and Mounting
64
Figure 1-9 Metropolis DMX and Fan Shelf Mounting Arrangement
65
Power Cable and Cable Bracket Installation
66
Table 1-2 Power Cable Assemblies
66
Figure 1-10 Cable Brackets
67
Figure 1-11 Power Connector Mounting Positions
68
Figure 1-12 Alternating Power Cable Routing
69
Figure 1-13 Power Connection
70
Figure 1-14 Power Cable Routing with Cable Bracket
71
Figure 1-15 Power Cable Routing Without Cable Bracket
72
Fan Shelf Power/Alarm Cable Installation
76
Table 1-6 Fan Shelf Cable Assembly
76
Figure 1-16 Fan Shelf Cable Connection
77
Table 1-4 Fan Shelf Cable Assembly
77
Table 1-5 Fan Shelf Cable Connections
78
Figure 1-17 Fan Shelf Cable Connection
79
Table 1-7 Fan Shelf Cable Connections
80
DS1 Cable Installation
81
Figure 1-18 DS1 Cable Installation
81
Figure 1-19 DS1 Cable Routing
82
Figure 1-19 DS1 Cable Routing
83
Table 1-8 DS1 Cable Assemblies
84
Table 1-9 DS1 Transmission Connections
85
DS3/EC-1 and TMUX Cable Installation
86
Table 1-10 DS3/EC-1 and TMUX Cable Assemblies
86
Figure 1-20 DS3/EC-1 and TMUX Cable Installation
87
Figure 1-21 DS3/EC-1 and TMUX Cable Routing
87
Table 1-11 DS3/EC-1 Transmission Connections
90
10/100Base-T Ethernet Cable Installation
92
Figure 1-22 10/100Base-T Cable Installation
93
Table 1-12 10/100Base-T Ethernet Cable Assemblies
94
Table 1-13 10/100Base-T Ethernet Connections
95
Figure 1-23 IAO LAN/TCP-IP Cable Installation to Front of Metropolis ® DMX
97
IAO LAN and TCP/IP Cable Installation
97
Table 1-14 LAN 10Baset Cable Assemblies
97
Figure 1-24 IAO LAN/TCP-IP Cable Installation to Rear of Metropolis DMX
99
Table 1-15 LAN 10Baset Cross-Over Cable Connections
100
Table 1-16 LAN 10Baset Straight-Through Cable Connections
101
Figure 1-25 Modem Cable Installation
102
Modem Cable Installation
102
Table 1-17 Modem Cable Assemblies
103
Table 1-18 Modem Cable Connection
103
Figure 1-26 TL1/X.25 Cable Connection and Placement
104
TL1/X.25 Interface Cable Installation
104
Table 1-19 X.25-AISW/X.25 Cable Assemblies
105
Table 1-20 X.25-AISW Interface Connections
106
Table 1-21 X.25-X.25 Interface Connections
106
Sync Cable Installation
107
Figure 1-27 Sync Cable with Connector Installation
108
Figure 1-28 Sync Cable with Wire-Wrap Connector Installation
109
Table 1-22 Synchronization Cable Assemblies (SYNC1 and SYNC2)
110
Table 1-23 Synchronization Cable (DS1 Timing Reference) Connections
110
Figure 1-29 Office Alarm Cable Installation
111
Office Alarm Cable Installation
111
Figure 1-30 Office Alarm Mult Cable Installation
113
Table 1-24 Office Alarm Cable Assemblies
115
Table 1-25 Office Alarm Connections
116
Miscellaneous (Environmental) Discrete Telemetry Cable Installation
117
Figure 1-31 Miscellaneous Discrete Cable Installation
118
Table 1-27 Miscellaneous (Environmental) Discrete Telemetry Connections
118
Table 1-26 Miscellaneous Discrete Cable Assemblies
119
Table 7-2 Miscellaneous (Environmental) Discrete Telemetry Connections
120
OC-48 Optical Fiber Cable Installation
121
OC-192 Optical Fiber Cable Installation
123
OC-3 Optical Fiber Cable Installation
125
OC-12 Optical Fiber Cable Installation
127
OC-48 (Low Speed) Optical Fiber Cable Installation
129
1000Base-F Cable Installation
131
CIT Cable Installation
133
Figure 1-32 CIT Cable Installation
134
Table 1-28 CIT Cable Assembly
134
Final Operations
137
Description
140
Equipment and Cable Installation
47
Powering and Initial Circuit Pack Installation
140
Powering
141
Table 1-3 Power Connections
142
Circuit Pack Compatibility
145
Table 2-2 Release 3.1.X Circuit Pack Compatibility
145
Initial Circuit Pack Installation
149
Figure 2-3 LNW26B Jumper Location
153
Figure 2-4 LNW121B - 159B Channel Positions
154
Figure 2-5 LNW221 - 259 Channel Positions
155
Part II Metropolis DMX High Capacity
167
Figure 2-6 High Capacity DMX Shelf Backplane
167
Metropolis DMX High Capacity Physical Installation and Powering
167
Overview
167
Tools, Test Equipment and Accessories
169
Equipment and Cable Installation for DMX High Capacity Shelf
173
Overview
173
Planning
175
Table 3-1 Cable Requirements and Options
177
Connector References
179
Figure 3-1 Connector Types and Pinouts
179
Inspection
180
Metropolis ® DMX High Capacity Shelf Installation
181
Figure 3-5 Typical Metropolis
186
Power Cable and Cable Bracket Installation
188
Table 3-2 Power Cable Assemblies
188
C O N T E N T S Lucent Technologies - Proprietary
189
Figure 3-6 Cable Brackets
189
Figure 3-7 Power Connector Mounting Positions
191
Figure 3-8 Alternating Power Cable Routing
192
Figure 3-9 Power Connection
193
Figure 3-10 Power Cable Routing with Cable Bracket
194
Figure 3-11 Power Cable Routing Without Cable Bracket
195
Table 3-3 Power Connections
198
Fiber Management Installation (Optional)
199
Installing the Fiber Ducts (Optional)
203
Cable and Optical Fiber Installation
204
DS1 Cable Installation
206
Figure 3-12 DS1 Cable Installation
206
Table 3-4 DS1 Cable Assemblies
206
Figure 3-13 DS1 Cable Routing
207
Figure 3-13 DS1 Cable Routing
208
Table 3-5 DS1 Transmission Connections
211
DS3/EC-1Cable Installation
213
Table 3-6 DS3/EC-1 Cable Assemblies
213
Figure 3-14 DS3/EC-1 Cable Installation
214
Figure 3-15 DS3/EC-1 Cable Routing
214
Table 3-7 DS3/EC-1 Transmission Connections
217
TMUX Cable Installation
222
Figure 3-16 TMUX Cable Installation
223
Figure 3-17 TMUX Cable Routing
223
10/100Base-T Ethernet Cable Installation
228
Figure 3-18 10/100Base-T Cable Installation
229
Table 3-11 10/100Base-T Ethernet Connections
229
Table 3-10 10/100Base-T Ethernet Cable Assemblies
230
IAO LAN and TCP/IP Cable Installation
232
Table 3-12 LAN 10Baset Cable Assemblies
232
Figure 3-19 IAO LAN/TCP-IP Cable Installation to Front of Metropolis
233
Figure 3-20 IAO LAN/TCP-IP Cable Installation to Rear of Metropolis DMX High Capacity
234
Table 3-13 LAN 10Baset Cross-Over Cable Connections
235
Table 3-14 LAN 10Baset Straight-Through Cable Connections
236
Modem Cable Installation
237
Figure 3-21 Modem Cable Installation
238
Table 3-15 Modem Cable Assemblies
238
Table 3-16 Modem Cable Connection
238
Figure 3-22 TL1/X.25 Cable Connection and Placement
239
TL1/X.25 Interface Cable Installation
239
Table 3-17 X.25-AISW/X.25 Cable Assemblies
240
Table 3-18 X.25-AISW Interface Connections
241
Table 3-19 X.25-X.25 Interface Connections
241
Figure 3-23 Sync Cable with Connector Installation
242
Sync Cable Installation
242
Figure 3-24 Sync Cable with Wire-Wrap Connector Installation
244
Table 3-20 Synchronization Cable Assemblies (SYNC1 and SYNC2)
245
Table 3-21 Synchronization Cable (DS1 Timing Reference) Connections
245
Office Alarm Cable Installation
246
Figure 3-25 Office Alarm Cable Installation
247
Figure 3-26 Office Alarm Mult Cable Installation
249
Table 3-22 Office Alarm Cable Assemblies
250
Table 3-23 Office Alarm Connections
251
Miscellaneous (Environmental) Discrete Telemetry Cable Installation
252
Figure 3-27 Miscellaneous Discrete Cable Installation
253
Table 3-24 Miscellaneous Discrete Cable Assemblies
254
Table 3-25 Miscellaneous (Environmental) Discrete Telemetry Connections
255
OC-48 Optical Fiber Cable Installation
256
OC-192 Optical Fiber Cable Installation
258
OC-3 Optical Fiber Cable Installation
260
OC-12 Optical Fiber Cable Installation
262
OC-48 (Low Speed) Optical Fiber Cable Installation
264
1000Base-F Cable Installation
266
CIT Cable Installation
268
Figure 3-28 CIT Cable Installation
268
Table 3-26 CIT Cable Assembly
269
Table 1-29 Standard CIT Cable Connection
270
Table 1-30 RJ-45 to DB-9 Connector Connections
271
Final Operations
272
4 Powering and Initial Circuit Pack Installation for DMX High
273
Capacity Shelf
273
Overview
273
Description
274
Powering
275
Figure 4-1 Power Connections on Metropolis
276
Circuit Pack Compatibility
279
Table 4-2 Release 3.1.X Circuit Pack Compatibility
279
Figure 4-2 Metropolis DMX High Capacity Shelf
282
Initial Circuit Pack Installation
283
Figure 4-3 LNW26B, LNW28, LNW77 Jumper Location
286
Figure 4-4 LNW121B - 159B Channel Positions
287
Figure 4-5 LNW221 - 259 Channel Positions
288
Part III Metropolis ® DMX Access Multiplexer Stand Alone
303
Installation Tests
303
Overview
303
Software Download and Circuit Pack Installation
305
5 Software Download and Circuit Pack Installation
307
Software Installation
307
Circuit Pack Installation
308
Use of Wavestar™ CIT Software
311
Use of Wavestar™ CIT Software
312
A Short Tour of the Command Builder
315
Circuit Pack Firmware Version Verification
319
Provision/Enable/Disable TCP/IP on an IAO Lan Port
322
Provision/Enable/Disable the Metropolis
326
Tcp/Ip Gne
326
Installation Tests
330
Overview
330
LBO Software Settings
331
Table 6-1 Cable Lengths (Feet)
332
Clearing Alarms
334
Local Equipment and Cross-Connect Tests
335
DS1 Protection Switching
340
DS1 Cleanup Procedures
345
DS3/EC1 and TMUX Testing Procedure
349
DS3 Protection Switching
356
LNW66 and LNW 71 (10/100T) TX Ethernet Cabling Testing
364
OC-3 Testing
370
Testing
375
OC-48 (Low Speed) Testing
381
LED Test
387
Additional Optical Tests (Optional)
388
Table 6-2 Minimum and Maximum TX (Dbm)
389
Figure 6-1 Optical Test Set Arrangement
390
Table 6-3 Transmission Rate
390
Figure 6-2 Optical Test Arrangement RX Fiber Moved
391
Operational Tests
394
Overview
394
Office Alarm Test
396
Table 7-1 Office Alarm Connections
397
Automatic Protection Switching and Alarm Test
401
Manual Switching Tests
405
External Timing Verification
407
Miscellaneous (Environmental) Discrete Telemetry Test
411
Figure 7-2 Miscellaneous (Environmental) Discrete Functions
413
TL1/X.25 Connection Test
415
Modem Connection Test
416
Final Operations
419
Part IV Metropolis
423
Overview
423
8 Ring Setup and Testing: Integration Procedures
426
Ring Setup and Testing: Integration Procedures
426
Overview
426
Fiber Installation
428
OC-48 Optical Transmission Test
434
OC-192 Optical Transmission Test
435
Automatic Protection Switching Test
436
Manual Switching Tests
438
Final Operations
443
Part V Metropolis ® DMX Access Multiplexer Supplementary
445
Information and Installation Checklist
445
Overview
445
A Laser Safety and Classifications
447
Overview
447
Laser Safety
448
Laser Product Classification
451
Table A-1 Laser Classes
452
Metropolis DMX Optical Specifications
453
Table A-2 Metropolis ® DMX Optical Specifications
453
B Fiber Cleaning
455
Fiber Cleaning
455
Overview
455
Equipment Requirements and Recommendations
457
Table B-1 Required and Recommended Equipment and Materials
457
Safety Instructions
458
Cleaning/Inspecting Optical Connectors
459
Figure B-1 Cleaning the Ferrule Endface
460
Figure B-2 Cletop Cleaner
461
Figure B-3 Acceptability Criteria for Fiber Cleaning
463
100 C Installing Fiber Connectors and Lbos
467
Installing Fiber Connectors and Lbos
467
Overview
467
Lbos
468
Figure C-1 LC-Type Connector Ports on Circuit Pack
468
Figure C-2 LC-Type LBO
469
Figure C-3 LC-Type LBO Inserted into LC-Type Connector Port
469
Figure C-4 Removing LC-Type LBO from LC-Type Connector Port
470
Fiber Connections
471
Figure C-5 LC-Type Fiber Connector
471
Figure C-6 LC-Type Fiber Connection
472
Backplane Pin Replacement
473
500 D Backplane Pin Replacement
474
Overview
474
Pin and Connector Background
475
Table D-1 Backplane Locations of METRAL™ Pins
476
Repair Kits and Tools
477
Table D-2 Metral™ Pins
477
Simple Repair Methods
478
Replacement Methods
480
Installation Checklist
483
Overview
483
Table E-1 Installation Acceptance Checklist
484
Fiber Labeling
491
Fiber Description
492
Fiber Labels
494
Acronyms and Abbreviations
495
Glossary
495
Issue 7, March
496
Terms and Definitions
511
Index
527
Advertisement
Lucent Technologies Metropolis Brochure (4 pages)
Wavelength Extension Solution
Brand:
Lucent Technologies
| Category:
Network Hardware
| Size: 0 MB
Advertisement
Related Products
Lucent Technologies Metropolis DMXplore
Lucent Technologies Metropolis DMXtend
Lucent Technologies Metropolis AMU Series
Lucent Technologies Metropolis ADM
Lucent Technologies MERLIN LEGEND Reporter
Lucent Technologies MERLIN LEGEND Release 3.1 Single-Line Telephone
Lucent Technologies Merlin Communications System
Lucent Technologies MERLIN LEGEND 3.1 Single-Line Telephone
Lucent Technologies MERLIN LEGEND 4.0 Single-Line Telephone
Lucent Technologies Merlin Magix
Lucent Technologies Categories
Telephone
Switch
Conference System
Software
Telephone System
More Lucent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL