Chemistry Config.
Wizard + to enter
Chemistry Configuration Wizard
Requires use of the optional AQL-CHEM Sensing Kit. Following the steps of the Chemistry Config.
Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if the chlorination function is
used, can configure the Pro Logic to generate the correct amount of chlorine to properly sanitize the
pool. Refer to the AQL-CHEM manual for more detailed information.
Pool/Spa Config.
+ to view/change
Pool/Spa Setup
Pool and Spa-Std
if "Pool and Spa-Dual" is selected
Heaters
Htr1=Spa,Htr2=Pool
if "Pool and Spa-Std" is selected
Spa - CountDn
00:30
if "Pool and Spa-Std or Dual" is selected
Spa Spillover
Enabled
if "Pool and Spa-Std or Dual" is
selected and if "Spa Spillover" is enabled
Filter Operation
Spa Spillover
if "Pool Only" or "Spa Only" is selected
V1=Aux1, V2=Aux2
Disabled
if "Pool and Spa-Std" is selected
Filter Off Valve
Change: Enabled
Pool/Spa Setup
If "Pool Only" or "Spa Only" are selected, then the pool/spa valves are not needed and pushing the
POOL/SPA button on the display/keypad will have no effect. If "Pool and Spa-Std" is selected, then
the pool/spa suction and return valve actuators should be connected to the Pro Logic. Pressing the
POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa
operation. If "Pool and Spa-Dual" is selected, then only the Pool/Spa return valve actuator should be
connected to the Pro Logic.
Heaters
This menu will only appear if Pool/Spa setup is set to "Pool and Spa-Dual". This allows the heater(s)
to either be shared between the pool and spa ("Shared" selected) or for Heater1 to be dedicated to the
spa and Heater2 to be dedicated to the pool ("Htr1=Spa, Htr2=Pool" selected).
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to "Pool and Spa-Std". This setting is the time,
after you manually switch the Pool/Spa valves to "Spa Only", until the Pro Logic automatically
returns the valves to their previous positions. It is programmed in increments of 5 minutes, from
"Manual On/Off" (0 minutes) to
Spa Spillover
When spa spillover is "Enabled" and "Pool and Spa-Std", the homeowner will be able to rotate
through "Pool Only" (both suction and return valves switched to pool), "Spa Only" (both suction and
return valves switched to spa) and "Spillover" (suction valve switched to pool and return valve
switched to spa) by successive presses of the "Pool/Spa" button. For "Pool and Spa-Dual", only
"Pool Only" and "Spillover" are available.
Press to access Chemistry Config. Wizard
Move to previous/next menu item
Push to access Pool/Spa options
Move to previous/next configuration menu
Rotates between Pool and Spa-Std
Pool Only, and Spa Only options
Move to next menu item
Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters
Move to next menu item
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
Move to next menu item
Toggle between Enabled and Disabled
Move to next menu item or previous/next configuration menu
Toggle between Pool Only
Move to previous/next configuration menu
Toggle between Enabled and Disabled (default)
Move to previous/next configuration menu
Toggle between Enabled
Move to previous/next configuration menu
(default)
, Pool and Spa-Dual,
(default)
Spa Spillover
(default)
and Spa Spillover options
(default)
and Disabled
"21:00" (21 hours).
The filter is forced on during this time period.