Super Chlorinate
The Pro Logic can be programmed to Super Chlorinate the pool or spa while running a group command. When the
Group starts, the Super Chlorinate cycle will begin. Super Chlorinate will continue until the preset time expires (see
Timers Menu/Super Chlorinate Hours) or until the Group turns off. Changing the Super Chlorinate state using the
Settings Menu, the Aqua Pod Super Chlorinate button, or a Super Chlorinate assigned Aux/Lights/Valve button
will temporarily cancel the Group's control of Super Chlorinate until the next time the Group is activated.
Variable Speed in Groups
The Pro Logic can be programmed to use alternate pump speeds while running group commands. This allows the
pump(s) to be set to a higher or lower speed than normal, while the group is activated. When the group stops, the
speed will return to its normal setting.
Changing the speed setting while the group is running will make the group release the alternate speed setting and
revert back to the normal speed setting. Any changes that are made at that point will affect the normal speed
setting. The next time the group is activated, the speed will return to the group speed setting that was originally
programmed in the Configuration Menu. To change the speed setting while the group is running, go to the Settings
menu and press the +/- button while "Group Control" is displayed. The speed setting will change to the normal
speed setting.
PS-8 and PS-16 Virtual Models
Pro Logic Virtual models are similar to standard PS models, but offer additional auxiliary outputs with limited
functionality. The PL-PS-8-V is similar to the PL-PS-4 with 4 additional Aux outputs. The PL-PS-16-V is similar
to the PL-PS-8 with 8 additional outputs. The additional aux outputs on virtual models can only be assigned to the
Super Chlorinate function (if the Chlorinator is enabled) or to a Group function. Refer to the following program-
ming information when assigning functions to the virtual auxiliary outputs.
Configuration Menus
Each item needs to be programmed and may contain additional sub-menu items. Refer to the following pages for
information on programming.
Chlor. Config.
Chlor. Config.
+ to view/change
+ to view/change
Chlorinator
Chlorinator
Enabled
Enabled
Display
Display
Salt
Salt
Cell Type
Cell Type
T-CELL-15
T-CELL-15
Chlorinator
Requires the use of a chlorinator cell and P-KIT sold separately. If the chlorinator is enabled, then
the cell and flow switch must also be installed and the Pro Logic will automatically chlorinate both the
pool and spa according to the desired output setting (see Settings Menu in the Operation manual). If
disabled (default), all displays relating to the chlorinator will be suppressed.
When the chlorinator is enabled, the Pro Logic will automatically detect and control any Aqua Rite(s)
that is installed in the system.
Display
Allows for the display of salt (default) or mineral values.
Cell Type Selection
The Cell Type Menu appears after "Display Salt/Minerals" in the Chlorinator Configuration Menu.
The options are T-CELL-15 (default), T-CELL-9, T-CELL-5 or T-CELL-3. Make the proper selection
based on the chlorinator cell that is used in your system. Refer to the information below.
"T-CELL-3" = T-CELL-3, GLX-CELL-3-W
"T-CELL-5" = GLX-CELL-5, GLX-CELL-5-W
"T-CELL-9" = T-CELL-9, GLX-CELL-9-W
"T-CELL-15" = T-CELL-15, GLX-CELL-15-W
Push to access Chlorinator option
Move to next configuration menu
Toggle between Chlorinator Enabled and Disabled (default)
Move to next menu item
Toggle between Display Salt (default) and Minerals
Move to previous/next configuration menu
Rotates between available Cell types
Move to next menu item