Hayward Pro Logic® Operation Manual page 31

Automation and chlorination pro logic series
Hide thumbs Also See for Pro Logic®:
Table of Contents

Advertisement

Aux1 Group
The Aux1 Group function allows the user to perform multiple tasks with a single push of the "Aux1"
button. When setting up a Group function, refer to page 15 for specific programming information.
There are two Group menus; the first menu determines how the group command will be initiated
(Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions
and their respective control parameters.
When activating Group functions, be aware that the most recent Group function that is initiated will
override any previous Group function.
Aux1 External Input Interlock
When Aux1 External Input Interlock is enabled, the Aux1 output will be forced off when the external
input is active. This will have precedence over freeze protection. Aux1 External Input Interlock is not
available for solar, low speed filter pump, dimmer, group, super chlorinate, or pH dispense functions.
Aux1 Freeze Protection
This function protects the pool, plumbing, and equipment against freeze damage. If Freeze Protection
is enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the
Pro Logic will turn on the aux relay to circulate the water. IMPORTANT: this only enables operation
of the AUX output during freeze--see the "Filter Pump Config." menu to enable freeze protection for
the main circulation system. Freeze Protection is not available for low speed filter pump, dimmer,
group, super chlorinate or pH dispense functions.
Aux1 Pump Speed
This is the speed of the filter pump when the Aux1 output is on. The default selection is "Settings
Menu". This is the speed of the pump that has been selected in the Settings Menu for normal filter
operation. If an alternate speed is desired when the Aux1 output is on, push "+" or "-" and select from
"Lowest" to "Highest" in 5% increments.
PL-PS-8-V models only:
PL-PS-16-V models only: Aux7 - Aux14 only
Aux7 Config.
+ to view/change
Aux7 Name
Cleaner
Aux7 Relay
Standard
Aux7 Function
Group
Aux7 Group
Timer: None(Manual)
Aux7 Group
Filter: Unaffected
For more information on the Group function, refer to page 15. If neither Super Chlorinate, ColorLogic or a Group
can be assigned to a Virtual Aux button, the following will be displayed:
No Virtual
Functions Available
Aux3 - Aux7 only
Push to access Virtual Aux options
Move to previous/next configuration menu
Rotates between all available names
Move to next menu item
Toggle between Standard (default) and ColorLogic (must be detected)
Move to next menu item or previous/next configuration menu
Rotates between Super Chlorinate,
Move to next menu item
Rotates between Manual On/Off (default),Countdown Timer and Timeclock
Move to next configuration menu item
Options available depend on the function that is selected
Move to previous/next menu item or next configuration menu
Group and Manual On/Off
28