Start/Stop Superchlorination; Program A Timeclock; Program A Countdown Timer; Enter/Exit Service Mode - Hayward Pro Logic® Operation Manual

Automation and chlorination pro logic series
Hide thumbs Also See for Pro Logic®:
Table of Contents

Advertisement

Note: Separate chlorinator output levels for the pool and spa must be set. If the valves are in
the pool-only or spa spillover positions, then the chlorinator will operate per the pool setting.
If the valves are in the spa-only position then the chlorinator will operate according to the spa
setting. The actual amount of chlorine introduced into the pool/spa is determined by: this
output setting, the amount of time the filter pump is running, the water temperature, and the
amount of salt in the water. Also see Start/Stop Supechlorination below.

Start/Stop Superchlorination

1. Press the "MENU" button repeatedly until "Settings Menu" is displayed
2. Press the ">" button repeatedly until "Super Chlorinate" is displayed.
3. The display will show whether superchlorination is "on" or "off".
4. Press "+" or "-" to toggle between "on" and "off"
Note: Once started, superchlorination will run for the programmed number of hours (Timers
Menu/Super Chlorinate Hours) or until you manually turn it off. Superchlorination may be
temporarily interrupted for a programmed spa operation.

Program a Timeclock

1. Press the "MENU" button repeatedly until "Timers Menu" is displayed
2. Press the ">" button repeatedly until the "xxx—all days" or "xxx—weekends" is displayed.
3. Use the "+" and "-" buttons to set the desired start time, then press ">" to switch to the off time. Use
the "+" and "-" buttons to adjust the off time. If you are setting the "weekend" timeclock, press ">" to
go to the "weekday" settings.
Note: During the programmed time, there may be other automatic or manual operations that
prevent the relay/valve from operating—see a more detailed discussion under Automatic Sys-
tem Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diagnostic Information.

Program a Countdown Timer

1. Press the "MENU" button repeatedly until "Timers Menu" is displayed
2. Press the ">" button repeatedly until the "xxx—CountDn" is displayed.
3. Use the "+" and "-" buttons to set the desired timer period.
Note: A setting of 0:00 will display as "Manual On/Off." The countdown automatic turn off
function is disabled by manual operation is still permitted. There may be other automatic or
manual operations that prevent the relay/valve from operating—see a more detailed discussion
under Automatic System Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diag-
nostic Information.
Enter/Exit Service (or Service—Timed) Mode
1. Go to Pro Logic main unit (normally mounted near the pool equipment)
2. Pressing the "Service" button rotates through normal operation (red LED off), service mode (red
LED on continuously) and service-timed mode (red LED flashing).
Note: This operation can only be performed at the main Pro Logic unit. Both "Service" and
"Service-Timed" disable all automatic programmed operations and allow manual operation
from the main unit only. The buttons on the remote display/keypads will still be able to turn
equipment off in case of an emergency, but will not turn any equipment on. If the system is in
"Serviced-Timed" it will automatically switch back to normal operation at the end of the time
period.
34