NetAXS™ NX4L1 Installation
Installation
11.If you are using a battery backup function, place the two 7 A-Hr batteries in the
12.Attach the 4-inch Battery-to-Battery cable from the positive (red) terminal of
13.Attach the positive (red) Power Supply-to-Battery cable to the remaining
14.Attach the negative (black) Power Supply-to-Battery cable to the remaining
15.For panels using the Ethernet connection, the cable clamp (HAS part number

4.1 Installing the Optional AC Inlet

Perform these steps to install the optional AC inlet (HAS part number 100-00049):
1. Remove the knockout piece at the lower-left side of the enclosure.
2. Feed the AC inlet assembly wires through the opening from the outside.
3. Push the receptacle straight in, until it snaps into place.
4. Connect each colored wire to its corresponding color on the terminal block.
5. Plug the AC inlet unit's power cord into the three-prong receptacle.
6. Plug the other end of the cable into a standard non-switched 115 VAC outlet.
Use only a Yung Li YC-12 power cord (HAS part number 700-0109). UL has
Note:
evaluated the use of this power cord with the optional AC inlet for the NX4L1. You
can purchase this power cord from Honeywell.
10
www.honeywell.com
enclosure with the battery terminals of each battery close to each other.
one battery to the negative (black) terminal of the other battery. DO NOT
CONNECT THE CABLE BETWEEN THE TERMINALS OF THE SAME
BATTERY.
positive (red) battery terminal.
negative (black) battery terminal.
3-000342) must be used for the panel to pass the FCC Part 15 Class B
requirements. Snap the clamp around any portion of the Ethernet cable that is
inside of the enclosure.