NetAXS™ NX4L1 Installation
Maintenance
• Use the following procedure to change the 3, 250 V, Bussman type GMA fuse
54
www.honeywell.com
in the power inlet terminal block.
Be sure to disconnect the AC power before removing the fuse holder
Warning:
from the power inlet terminal block.
To reduce the risk of fire, replace the fuse only with a 3 A, 250 V,
Warning:
Bussman type GMA fuse.
1.Disconnect the AC power.
2.Remove the fuse holder from the power inlet terminal block (see
page 6 to identify the location of the power inlet terminal block).
3.Replace the blown fuse in the lower section of the fuse holder with the new
fuse. The upper section of the fuse holder provides a convenient location for
a spare fuse.
4.Slide the fuse holder back into the power inlet terminal block.
5.Re-connect the AC power.
Figure 1