13.2.3. Command mode

In the command mode, the scale is controlled by commands that come from an
external device such as a personal computer.
Command List
Command
Q
Send data immediately.
Z
Zero the scale when the weight is stable.
T
Tare the scale when the data is stable.
U
Switch the weighing unit.
When the five-level comparator mode is used:
?H2
When the three-level comparator mode is used:
When the five-level comparator mode is used:
?H1
When the three-level comparator mode is used:
When the five-level comparator mode is used:
?L1
When the three-level comparator mode is used:
When the five-level comparator mode is used:
?L2
When the three-level comparator mode is used:
When the five-level comparator mode is used:
H2
When the three-level comparator mode is used:
When the five-level comparator mode is used:
H1
When the three-level comparator mode is used:
When the five-level comparator mode is used:
L1
When the three-level comparator mode is used:
When the five-level comparator mode is used:
L2
When the three-level comparator mode is used:
Description
Send the current HIHI limit value.
Send the current HI limit value.
Send the current HI limit value.
Not used
Send the current LO limit value.
Not used
Send the current LOLO limit value.
Send the current LO limit value.
Set the HIHI limit value.
Set the HI limit value.
Set the HI limit value.
Not used.
Set the LO limit value.
Not used.
Set the LOLO limit value.
Set the LO limit value.
Same as the ZERO switch.
Same as the TARE switch.
Same as the UNITS switch.
Send a setting value.
Function settings
Set the six-digit value excluding
the polarity and decimal point
31
Remarks
Cp-l 0
Five-level (
Cp-l 1
Three-level (
)
)