Summary of Contents for A&D SJ-1000H

  • Page 1 SJ-1000H SJ-2000H SJ-5000H SJ-12KH WM+PD4001280A...
  • Page 2: Safety Precautions

    SAFETY PRECAUTIONS All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: A potentially hazardous situation which, if not avoided, WARNING could result in death or serious injury. A potentially hazardous situation which, if not avoided, CAUTION may result in minor or moderate injury.
  • Page 3: Parts Description

    PARTS DESCRIPTION Weighing Platform ON/OFF key Spirit level Turns the scale power on/off. UNITS key Changes weighing units, (k)g, lb, oz or lb-oz. RE-ZERO key Display Sets display to zero or subtracts weight of container. Battery cover AC adapter jack Four leveling feet Battery indicator Indicates battery remaining amount.
  • Page 4: Installing Batteries

    PREPARATION Installing Batteries CAUTION Take great care of the polarity of batteries. The polarity marks are shown in the battery box. Replace used batteries with four new ones when is displayed. Do not mix used and new batteries. Do not mix the battery type. Remove batteries when the scale is not to be used for a long time.
  • Page 5: Weighing Procedures

    WEIGHING Before Weighing Automatic power-off function. If the scale left ON and the stable indicator is displayed, an automatic power-off function turns power off after approximately 5 minutes. To disable/enable this function, turn the scale on while pressing the poff0 poff1 [RE-ZERO] key.
  • Page 6: When To Calibrate

    CALIBRATION When to Calibrate Calibration may be required when it initially installed or it is moved a substantial distance. Also periodical calibration will be recommended. Calibration using a Calibration Weight Calibration switch 1. Enter calibration mode. Press the [ON/OFF] key to turn the power off. While pressing both the [RE-ZERO] and [UNITS] keys, press the [ON/OFF] key.
  • Page 7: Specifications

    SPECIFICATIONS MODEL SJ-1000H SJ-2000H SJ-5000H SJ-12KH (k)g 1000 g x 0.5 g 2000 g x 1 g 5000 g x 2 g 12 kg x 5g Capacity 2.2 lb x 0.001 lb 4.4 lb x 0.002 lb 11 lb x 0.005 lb 26 lb x 0.01 lb 35 oz x 0.02 oz 70 oz x 0.05 oz 176 oz x 0.1 oz 423 oz x 0.2 oz Resolution lb-oz 2.2 lb x 0.1 oz 4.4 lb x 0.1 oz...
  • Page 8 3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 http://www.aandd.co.jp/ A&D ENGINEERING, INC. 1555, McCandless Drive, Milpitas, CA. 95035 U.S.A. Telephone: [1] (408) 263-5333 Fax: [1] (408)263-0119 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxon OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 <German Scales Office>...