Brother ZE-855A Instruction Manual page 197

Electronic single needle zigzag lock stitcher; electronic single needle zigzag lock stitcher with thread trimmer
Hide thumbs Also See for ZE-855A:
Table of Contents

Advertisement

I Memory switches 01~18
01
02 Interlock release when treadle is depressed
03
04 Independent backtack speed setting
05
06 Increased piercing force
07
08
11 No thread trimming/thread wiping
12 Presser foot status after thread trimming
13 Presser foot status when treadle stopped
at neutral position
14 Actuator function
15 Decelerated stop control
16
17 Half-stitch correction
18 Reverse correction
*1:Items to the left of the "/" are when the correction sewing indicator is on, and to the right are when it is off.
I Memory switches 21~28
21
22
23
24
25
26 End backtacking movement control
27
28
ON (Cannot be changed)
OFF
ON Forward treadle operations enabled when depressing treadle
backward (during thread trimming / needle rising)
OFF Forward treadle operations disabled when depressing treadle
backward (during thread trimming / needle rising)
ON (Do not change)
OFF
ON Backtacking speed is not limited by panel setting speed
OFF Backtacking speed is limited by pannel setting speed
ON (Do not change)
OFF
ON No increased piercing force operation
OFF Increased piercing force operation
ON (Do not change)
OFF
ON (Do not change)
OFF
ON Operation selection possible using thread trimming / needle raising key
OFF Thread trimming and thread wiping operate
ON Presser foot rises at neutral position
OFF Presser foot lowered at neutral position
ON Raised
OFF Lowered
ON Operates as thread trimming switch
OFF Normal functioning
ON No decelerated stop control
OFF Control prevents extra stitch from being sewn
ON (Do not change)
OFF
ON One stitch forward correction/Half-stitch forward correction (*1)
OFF One stitch forward correction/No correction (*1)
ON One stitch forward correction/Reverse correction (*1)
OFF One stitch forward correction/No correction (*1)
ON (Do not change)
OFF
ON (Do not change)
OFF
ON (Do not change)
OFF
ON (Do not change)
OFF
ON (Do not change)
OFF
ON Moves to end backtacking without decelerating to low speed
OFF Decelerates to low speed, and then moves to end backtacking
ON (Do not change)
OFF
ON (Do not change)
OFF
ZE-855A,856A
13. STANDARD ADJUSTMENTS
13. STANDARDEINSTELLUNGEN
13. REGLAGES STANDARD
13. AJUSTES ESTANDARES
178

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ze-856a