Tape Drive Problems - HP ProLiant DL985 Troubleshooting Manual

Hp proliant servers troubleshooting guide
Hide thumbs Also See for ProLiant DL985:
Table of Contents

Advertisement

If the server includes PPMs that are not integrated on the system board, remove all PPMs from the
b.
server except for the PPM associated with the remaining processor.
Replace the remaining processor with a known functional processor. If the problem is resolved after
c.
you restart the server, a fault exists with one or more of the original processors. Install each
processor and its associated PPM (if applicable) one by one, restarting each time, to find the faulty
processor or processors. At each step, be sure the server supports the processor configurations.

Tape drive problems

The following sections include the most common tape drive issues. Actions are listed in the order that they
should be tried. If the issue is resolved, it is not necessary to complete the remaining actions.
All actions may not apply to all tape drives.
For detailed tape drive guided troubleshooting information, see the HP website
(http://www.hp.com/support/gts).
To download HP StorageWorks Library and Tape Tools, see the HP website
(http://www.hp.com/support/tapetools).
For more information about common tasks, see the HP website (http://www.hp.com/support/lttfaq).
Stuck tape issue
Action:
Manually press the Eject button. Allow up to 10 minutes for the tape to rewind and eject.
1.
Perform a forced eject:
2.
Press and hold the Eject button for at least 10 seconds.
a.
Allow up to 10 minutes for the tape to rewind and eject. The green Ready LED should flash.
b.
Power cycle the drive. Allow up to 10 minutes for the drive to become ready again.
3.
Check for conflicts in backup software services.
4.
Check the SCSI/HBA/Driver configuration of the drive.
5.
Inspect media and cables, and discard any that are faulty or damaged.
6.
Contact HP support
7.
Read/write issue
Action:
Run the Drive Assessment Test in HP StorageWorks Library and Tape Tools.
1.
CAUTION:
the tape, run the logs-based Device Analysis Test instead.
Run the Media Assessment Test in HP StorageWorks Library and Tape Tools. This is a read-only test.
2.
Backup issue
Action:
Run the Drive Assessment Test in HP StorageWorks Library and Tape Tools.
1.
("Contacting HP technical support or an authorized
Running the Drive Assessment Test overwrites the tape. If it is not possible to overwrite
reseller" on page 177).
Hardware problems 52

Advertisement

Table of Contents
loading

Table of Contents