404-Parallel Port Address Conflict Detected...
...A hardware conflict in your system is keeping some system components from working correctly. If you have recently
added new hardware remove it to see if it is the cause of the conflict. Alternatively, use Computer Setup or your
operating system to insure that no conflicts exist.
Audible Beeps: 2 short
Possible Cause: A hardware conflict in the system is preventing the parallel port from working correctly.
Action:
If you have recently added new hardware, remove it to see if the hardware is the cause of the conflict.
1.
Run the server setup utility to reassign resources for the parallel port and manually resolve the resource
2.
conflict.
Run Insight Diagnostics
3.
indicated.

600 Series

601-Diskette Controller Error
Audible Beeps: None
Possible Cause: Diskette controller circuitry failure occurred.
Action:
Be sure the diskette drive cables are connected.
1.
Replace the diskette drive, the cable, or both.
2.
Run Insight Diagnostics
3.
indicated.
602-Diskette Boot Record Error
Audible Beeps: None
Possible Cause: The boot sector on the boot disk is corrupt.
Action:
Remove the diskette from the diskette drive.
1.
Replace the diskette in the drive.
2.
Reformat the diskette.
3.
605-Diskette Drive Type Error.
Audible Beeps: 2 short
Possible Cause: Mismatch in drive type occurred.
Action: Run the server setup utility to set the diskette drive type correctly.
("HP Insight
Diagnostics" on page 76) and replace failed components as
("HP Insight
Diagnostics" on page 76) and replace failed components as
Error messages 135