HP ProLiant DL985 Troubleshooting Manual page 139

Hp proliant servers troubleshooting guide
Hide thumbs Also See for ProLiant DL985:
Table of Contents

Advertisement

Be sure the assembly is properly connected and each fan is properly seated.
2.
If the problem persists, replace the failed fans.
3.
If a known working replacement fan is not spinning, replace the assembly.
4.
1611-Power Supply Zone Fan Assembly Failure Detected. Single fan...
...failure. Assembly will provide adequate cooling.
Audible Beeps: None
Possible Cause: Required fan is not spinning.
Action: Replace the failed fan to provide redundancy, if applicable.
1611-Primary Fan Failure (Fan Zone System)
Audible Beeps: None
Possible Cause: A required fan is not spinning.
Action: Replace the failed fan.
1611-Redundant Fan Failure (Fan Zone System)
Audible Beeps: None
Possible Cause: A redundant fan is not spinning.
Action: Replace the failed fan.
1612-Primary Power Supply Failure
Audible Beeps: 2 short
Possible Cause: Primary power supply has failed.
Action: Replace power supply.
1615-Power Supply Configuration Error
Audible Beeps: None
Possible Cause: The server configuration requires an additional power supply. A moving bar is displayed,
indicating that the system is waiting for another power supply to be installed.
Action: Install the additional power supply.
1615-Power Supply Configuration Error
- A working power supply must be installed in Bay 1 for proper cooling.
- System Halted!
Audible Beeps: None
Possible Cause: The server configuration requires an additional power supply. A moving bar is displayed,
indicating that the system is waiting for another power supply to be installed.
Action: Install the additional power supply.
Error messages 139