Set Configuration Command Issued - HP ProLiant DL985 Troubleshooting Manual

Hp proliant servers troubleshooting guide
Hide thumbs Also See for ProLiant DL985:
Table of Contents

Advertisement

Description: SMART is unable to communicate with the drive, because the cable is not securely connected, or
the drive cage connection has failed.
Action:
Power down the system.
1.
Reconnect the cable securely.
2.
Restart the system.
3.
If the problem persists, replace the cables and connectors as needed.
4.
SCSI Port X, Drive ID Y RIS Copies Within This Drive Do Not Match
Description: The copies of RIS on the drive do not match.
Action: Check for other errors. The drive may need to be replaced.
SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected in
the Factory Monitor and Performance Data...
...SOLUTION: Please replace this drive when conditions permit.
Description: A predictive failure warning for this hard drive has been generated, indicating that a drive
failure is imminent.
Action: Replace this drive at the earliest opportunity. Refer to the server documentation for drive replacement
information before performing this operation.
SCSI Port X, Drive ID Y...S.M.A.R.T. Predictive Failure Errors Have Been Detected in
the Power Monitor and Performance Data...
...SOLUTION: Please replace this drive when conditions permit.
Description: A predictive failure warning for this hard drive has been generated, indicating a drive failure is
imminent.
Action: Replace this drive at the earliest opportunity. Refer to the server documentation for drive replacement
information before performing this operation.
SCSI Port X, Drive ID Y Was Replaced On a Good Volume: (failure message)
Description: ADU
no problem occurred with the volume.
Action: No action is required.

Set Configuration Command Issued

Description: The configuration of the array controller has been updated. The array accelerator board may
remain disabled until it is reinitialized.
Action: Run the server setup utility to reinitialize the array accelerator board.
("Array diagnostic
software" on page 77) found that this drive was replaced, even though
Error messages 105