Miscellaneous Port 85 Codes - HP ProLiant DL985 Troubleshooting Manual

Hp proliant servers troubleshooting guide
Hide thumbs Also See for ProLiant DL985:
Table of Contents

Advertisement

CAUTION:
provided in "Performing processor procedures in the troubleshooting process (on page 17)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Remove all processors and PPMs, except the processor installed in socket 1 and the corresponding
3.
PPM.
Install the expansion boards one at a time, rebooting between each installation to isolate the failed
4.
expansion board.
Replace the failed expansion board, if applicable.
5.
Replace the PCI riser board, if applicable.
6.
Replace the system board.
7.
IMPORTANT:
serial number through RBSU

Miscellaneous port 85 codes

To troubleshoot all other port 85 codes:
IMPORTANT:
continues, proceed with the next step.
Bring the server to base configuration by removing all components that are not required by the server
1.
to complete POST. For more information, see "Breaking the server down to the minimum hardware
configuration (on page 17)." This process can include removing all:
Expansion boards
o
DIMMs, except the first bank
o
Hard drives
o
Peripheral devices
o
IMPORTANT:
not function properly.
CAUTION:
provided in "Performing processor procedures in the troubleshooting process (on page 17)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Remove all processors and PPMs, except the processor installed in socket 1 and the corresponding
2.
PPM.
Install each remaining system component, rebooting between each installation to isolate any failed
3.
components.
Clear the system NVRAM.
4.
Replace the system board.
5.
IMPORTANT:
serial number through RBSU
Before removing or replacing any processors, be sure to follow the guidelines
If replacing the system board or clearing NVRAM, you must re-enter the server
("Re-entering the serial number and product
Reboot the server after completing each numbered step. If the error condition
Processor socket 1 and PPM slot 1 must be populated at all times or the server does
Before removing or replacing any processors, be sure to follow the guidelines
If replacing the system board or clearing NVRAM, you must re-enter the server
("Re-entering the serial number and product
ID" on page 72).
ID" on page 72).
Error messages 170