System Fans Not Redundant
Event Type: Fans not redundant
Action: Add a fan or replace the failed fan.
System Overheating (Zone X, Location)
Event Type: Overheating condition
Action: Check fans.
System Power Supplies Not Redundant
Event Type: Power supply not redundant
Action: Add a power supply or replace the failed power supply.
System Power Supply Failure (Power Supply X)
Event Type: Power supply failure
Action: Replace the power supply.
Unrecoverable Host Bus Data Parity Error...
...Unrecoverable Host Bus Address Parity Error
Event Type: Host bus error
CAUTION:
board. If you believe the system board requires replacement, contact HP Technical Support
("Contacting
Action: Replace the board on which the processor is installed.
Uncorrectable Memory Error (Slot X, Memory Module Y)...
...Uncorrectable Memory Error (System Memory)
Uncorrectable Memory Error (Memory Module Unknown)
Event Type: Uncorrectable error
Action: Replace the memory module. If the problem persists, replace the memory board.
HP BladeSystem p-Class infrastructure error codes
The server blade management modules and power management modules contain service ports that enable
service personnel to gather fault information.
To gather the fault information:
Connect to the service port. For more information, refer to the HP BladeSystem Maintenance and
1.
Service Guide on the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info).
Only authorized technicians trained by HP should attempt to remove the system
HP" on page 177) before proceeding.