Disk Drive Filler Panels

100 Servicing & Upgrading
There are two types of disk filler panels: the larger type B shown in
and the smaller type A shown in
identified by the blue release tab and the locking cam lever.
Caution
Do not operate the array for more than 5 minutes with a disk
drive or filler panel removed. Either a disk drive or filler panel
must be installed in the slot to maintain proper airflow.
Make sure you install the correct type of filler panel. If the wrong
panel is used, it may become stuck in the enclosure. Before
installing a filler panel, make sure it is the same type as the other
filler panels in the enclosure.
Removing a Type B Disk Drive Filler Panel
1
Push down the release tab
2
Pull the disk drive filler panel (3) out of the slot.
Installing a Type B Disk Drive Filler Panel
1
Push down the release tab
2
Push the filler panel (3) firmly into the slot.
3
Push down the cam lever until it clicks into place.
Removing a Type A Disk Drive Filler Panel
Pull the disk drive filler panel out of the slot
Installing a Type A Disk Drive Filler Panel
Push the filler panel firmly into the slot.
Figure
36. The type B filler panel can be
(Figure
35, 1) and pull up the cam lever (2).
(Figure
35, 1) and pull up the cam lever (2).
(Figure
Figure 35
36).