Command
help
setup
dsp
cfg
mgr
fmt
rbld
recover
secure
log
scsi
Usage Notes
Ø
To maintain consistency with earlier versions of the VFP, all commands can be prefaced with "vfp".
Ø
For help with a specific command, use the -? Option. For example, setup -?
Ø
For command recall, type "<" or ">".
Command
Options and Arguments
setup
-e {on | off}
-r <value>
-c <value>
-b <int>
dsp
dsp (no argument follows)
-c [m/c1 | m/c2]
-d [fruLocation]
-L [LUN ID]
-s
-e
-f
VA Virtual Front Panel Commands
HP15 Firmware Release
April, 2002
Function
Displays a description of each command.
Performs Virtual Front Panel configuration.
Displays subsystem status.
Performs subsystem configuration (LUN creation).
Performs subsystem management operations.
Performs an subsystem format.
Performs rebuild operations.
Performs NVRAM recovery operations.
Performs security operations.
Displays Logs
Performs scsi command for provided cdb.
Description
-e: Sets character echo
-r: Sets the number of rows:
<value>: range 5 – 1000
-c: Sets the number of columns:
<value>: ranger 40 - 8000
-b: Sets baud rate
<int> : 0, 1, 2, or 3
for 9600, 19200, 38400, 57600
Note: A firmware reset will restore the
default value of 9600.
Displays general information about the
subsystem.
-c: display controller information:
m/c1: controller 1, m/c2 controller 2
-d: display drive information:
[fruLocation] m/d#
-L: display LUN information (default for
all existing luns).
[LUN ID]: specify a requested LunID
-s: display subsystem settings
-e: enclosure information
-f: list of discovered FRUs

Advertisement

loading

Summary of Contents for HP StorageWorks 7110 - Virtual Array

  • Page 1 VA Virtual Front Panel Commands HP15 Firmware Release April, 2002 Command Function help Displays a description of each command. setup Performs Virtual Front Panel configuration. Displays subsystem status. Performs subsystem configuration (LUN creation). Performs subsystem management operations. Performs an subsystem format. rbld Performs rebuild operations.
  • Page 2 cfg -L <LUN ID> -a <capacity> [{G|g}|{K|k}] –g <RG Id> To Create a LUN requires three parameters, LUN ID, capacity and RD -L <LUN ID>: specify LUN ID to be created. -a <capacity>: specify LUN capacity. Capacity is default to MB. If followed by ‘K’...
  • Page 3 -s {shut | start} -s: Shutdown or restart the disk array -R {full | partial} -R: Reset the disk array -L <loop id> -c {1|2} -L: Set the FC Port Loop ID for the Controller Port. -t {1 | 2 | 4} –c {1|2} -t: Set the topology for the Controller Port.
  • Page 4 rbld -p: Displays status/progress of a subsystem rebuild. -a {on | off} -a: enables or disables autorebuild recover No options Perform a recover process. Will ask for user’s verification to proceed. -s: returns the recoverability status or the disk array, as well as the status of the recovery progress.