Security Menu (continued)
Feature
Video Blanking
Power Switch
Inhibit

Server Menu

Feature
System Management
Console Redirection
Event Log Configuration
Service Boot
Assert NMI on PERR
Assert NMI on SERR
FRB-2 Policy
BMC IRQ
After Power Failure
Temperature Sensor
POST Error Pause
Platform Event Filtering
50
Choices
Description
Disabled
Blank video when secure mode is activated. A pass word is required
Enabled
to unlock the system.
This option only appears on the screen after a "user" password has
been entered.
Disabled
When enabled, the power switch is inoperable.
Enabled
This option only appears on the screen after a "user" password has
been entered.
Choices
Press <Enter>
Press <Enter>
Press <Enter>
Enable
Disable
Disabled
Enabled
Disabled
Enabled
Disable BSP
Do not Disable BSP
Retry 3 Times
Disabled
IRQ 5
IRQ 11
Stays Off
Last State
Power On
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Description
Enters Submenu.
Enters Submenu.
Enters Submenu
If enabled, server boots directly to System
Management.
If enabled, PCI bus parity error (PERR) routes to NMI.
If enabled, PCI bus system error (SERR) routes to NMI.
Controls the policy of the FRB-2 timeout. This option
determines when the Boot Strap Processor (BSP)
should be disabled if an FRB-2 error occurs.
Sets the BMC IRQ.
Determines the mode of operation if a power loss
occurs.
If enabled, the system will not boot if the ambient
system temperature is outside the range specified in the
Sensor Data Record (SDR).
If enabled, the system will wait for user intervention on
critical POST errors.
Enable/Disable triggers for system sensor events inside
the Baseboard Management Controller (BMC).
Intel Server Board SCB2 Product Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scb2scsi

Table of Contents