Setting Up Raid 5 Arrays On An Hp Netserver Cluster - HP D7171A - NetServer - LPr Configuration Manual

Microsoft cluster installation documentation
Hide thumbs Also See for D7171A - NetServer - LPr:
Table of Contents

Advertisement

1.
Click Next.
The Configuration Wizard displays its Logical Drive Definition window.
2.
The Logical Drive Definition window shows the array's RAID level (RAID 1) and its usable size.
Notice that the size of the array is one half of the sum of the capacity of the two drives composing the
array, since all data is duplicated.
3.
Click Advanced and verify that Write Policy is set to "Write Thru" and then click OK.
4.
Click Accept to set the array parameters.
5.
If you:
want to define another array, click Back and repeat the steps
listed above starting with step 3 in Define Array.
have identified all your arrays, click Next, Finish, and then
OK.
NetRAID Assistant saves the array configuration and prompts
that the array configuration has changed. Click OK.
Initialize the Array
After you have defined the cluster's arrays, you need to initialize the arrays you defined. HP NetRAID Assistant
initializes all arrays you have defined at the same time. To initialize all the arrays:
1.
At the "Would you like to Initialize?" prompt, click OK.
HP NetRAID Initialization may be time consuming. Plan on 5 to 15 minutes per array.
2.
When NetRAID initialization is complete, exit NetRAID Assistant.
3.
Continue configuration using Windows NT Disk Administrator.
When you have finished defining and configuring the cluster's arrays using HP NetRAID Assistant, return to Part 5
and finish array configuration using the Windows NT Disk Administrator utility.

Setting Up RAID 5 Arrays on an HP NetServer Cluster

The HP NetRAID adapter and proprietary HP NetRAID software can be used to organize the cluster's disk storage
into RAID level 5 disk arrays. Each level 5 RAID array is composed of three hard (hot swap) drives located in
external shared storage cabinets.
RAID level 5 (striping with distributed parity) provides storage redundancy with good overall performance and a
minimum loss in storage capacity. With RAID 5 the equivalent of only one hard drive in the array is used for
redundancy. Note that each array supporting RAID 5 logical disks requires at least three physical drives.
Stripe
1
HP NetServer LH Pro Microsoft Cluster Installation Guide - 1 October 1997
Raid Level 5 Parity Distribution
Disk 1
Block 1.1
Block 1.2
Appendix C RAID Array Configuration
Disk 2
Disk 3
Parity 1