Assigning SCSI IDs
To configure the shared disks, you need to change the SCSI ID assignments for each of the HP Storage System/6
units you are including in the cluster:
1.
Check, and if necessary re-assign, SCSI ID's for both the upper and lower cages. Configure the DIP
switches as indicated in the figure below. Note that the upper cage settings are shown in their default
positions.
2.
Reattach and close the HP Storage System/6 door. Replace the front bezel. Leave the power off.
The HP Storage System/6 must be operated with the door closed to ensure proper airflow and to prevent
radio frequency interference.
Repeat Steps 1-2 for each HP Storage System/6 to be included in the cluster.
When you have finished, the hardware configuration of the Storage System/6 is complete. You are now ready to
proceed to "Part 3: Configuring the HP NetRAID Adapter."
WARNING
Do not cable the shared storage units to System A and B at this time. You must configure the HP
NetRAID Adapter (Part 3), and install Microsoft Windows NT Server, Enterprise Edition (Part 4) before attaching
the HP Storage System/6.
HP NetServer LH Pro Microsoft Cluster Installation Guide - 1 October 1997
HP Storage System/6 DIP Switch and Cluster Assignments
Part 2: Setting Up the HP Storage System/6