Temperature in degrees Celsius for all temperature sensors
o
•
Access level/Bay level:
All
Bay specific
•
Restrictions:
None
Example
OA-0018FE27577F> SHOW ENCLOSURE TEMP
Locale
-------------------------- -----------
Enclosure
Onboard Administrator
Blade Bay
Blade Bay
Blade Bay
Blade Bay
Interconnect Module
SHOW FRU
•
Command:
SHOW FRU
•
Description:
The FRU Summary section provides information on all field replaceable units within the enclosure.
o
Information provided in this section can quickly aid the administrator in contacting HP Customer
o
Service for troubleshooting, repair, and ordering replacements.
•
Access level/Bay level:
All
Bay specific
•
Restrictions:
You must have access to the specified bay.
Example
OA-0018FE27577F> show fru
Enclosure
Model: BladeSystem c3000 Enclosure
Manufacturer: HP
Serial Number: 0987654321
Part Number: 437506-B21
Enclosure Midplane
Manufacturer: HP
Spare Part Number: 441829-001
Onboard Administrator 1
Model: BladeSystem c3000 Onboard Administrator
Manufacturer: HP
Serial Number: P30590A9VUQ04B
Temp Status
--------
OK
26C/ 78F
1 OK
26C/ 78F
7 N/A
20C/ 68F
8 N/A
25C/ 77F
2A N/A
25C/ 77F
2B N/A
27C/ 80F
1 OK
Temp
Caution
Critical
-------
--------
75C
75C
38C
45C
40C
40C
80C
80C
43C
60C
45C
45C
Enclosure management commands 85